11
Changing coolant
Fig. 6-12 Changing coolant
Park the machine in horizontal position.
Shut down the engine and allow the cooling system to cool down.
Place a collecting vessel under the combined cooler.
Carefully unscrew the filler cap (3), until all pressure has been relieved from
the combined cooler.
Remove the cap (3) from the combined cooler.
Unscrew the water-drain plug (1) on the drain hose (2) and drain coolant.
If necessary, flush the cooling system with water.
Close the water-drain plug on the combined cooler again.
Fill the cooling system with coolant and close the radiator cap. See chapter
6.4.2 "Consumables", page 52.
Start the engine and run it until operating temperature is reached.
Shut down the engine and let it cool down.
Check the coolant level and top up coolant (if necessary, several times).
Danger of scalding by hot oil.
Z Only open the radiator cap
when the engine is cold.
Z Wear suitable protective
clothing and safety goggles.