TL260
Maintenance
74 / 187
6
06_Maintenance_en.fm - V 0.1 - 14.4.11
11
Automatically Switch the “motor cooling fan” switch to the forward switch position.
J The cooling fins are automatically cleaned at regular intervals.
J Due to the automatic reverse of the running direction of the fan, the dirt is
removed from the cooling fins.
If there is increased exposure to dust, the cooler fins are subject to premature
contamination:
Switch intermittently to the rear switch position in order to additionally clean
the combined cooler.
Subsequently return to the forward switch position.
Manually
Switch the “motor cooling fan” switch to the rear switch position.
J The fan stops rotating. Then it runs for approx. 12 sec into the opposite
direction.
J The dirt is removed from the cooling fins.
J The fan stops rotating. The switch is now in the center position.
Temperature-
controlled
If the machine is used indoors (warehouses), switch the “motor cooling fan”
switch to the center position.
J The fan does not reverse the direction of rotation.
If required, clean the equipment manually in outdoor environments.