34 DHB MPE850 UTV Rev A | 409135 |
2
3
1
6 Test procedures at engine
6.2 Checking generator
6.2 Checking generator
G1 Generator
Stator
2
Rotor
3
GX1 3-pole connection at
stator generator (yellow
wires)
1
Check all electrical contacts for corrosion and proper mechanical connection.
Make a continuity test with all relevant wires:
Continuity test with multimeter:
d Continuity is required
(Resistance 0,3 ohm ±0,1 ohm at 20 °C)
No continuity is permitted
GX1- Engine
ground
A B C
GX1- A d d
B d
C
Engine ground
If the wires are defective, replace the stator.
Perform a visual inspection of the rotor.
If mechanical defects are present, for example at the internal magnets, replace the rotor.