15
55.
Control Input Terminals 1 – 8 [CTRL IN 1 – 8, G]
Control input terminals for general broadcasts.
Functions assigned to each contact input are
determined by software settings. (For details,
refer to "Event Settings" in the separate software
manual.)
56. Audio Input 4 Terminals [INPUT 4]
(VM-3240VA only)
Electronically-balanced 600 Ω, –10 dB* / –50 dB,
screw terminal. Use DIP switch (40) for
LINE/MIC switching.
*
0 dB = 1 V
57. Remote VOL Terminals 1 & 2 [REMOTE VOL]
Not used.
58. Input 4 Volume Control
(VM-3240VA only)
Adjusts the audio input 4’s (56) input volume.
59. External Amplifier Link Connector [EXT. PA
LINK]
Not used.
60. VM Link Connector [VM Link Out]
Connects to the VM-3240E’s VM Link In
connector.
61. LAN Connector [LAN]
(VM-3240VA only)
Connects to a PC.
62. Remote Microphone Link Connectors 1 & 2
[RM1 LINK IN, RM2 LINK IN]
(VM-3240VA only)
Connect the RM-200M Remote Microphone to
these connectors.
63. DIP Switch (VM-3240E only)
Used for unit ID and equipment settings.
DIP Switches 1 & 2 [LOCAL INPUT]
Not used. Default setting: OFF
DIP Switches 3 – 6 [EXTENSION UNIT NO.]
Used for unit ID settings for the VM-3240E.
(Refer to "Connections between VM Amplifiers"
on page 96 for ID settings.)
Default settings: ON (Switch 3), OFF (Switches 4
– 6)
DIP Switch 7 [FIRMWARE]
Set this switch to ON to enable firmware version
updates, and OFF to prohibit the update.
Default setting: ON
DIP Switch 8 [CONFIG]
Not used.
Default setting: ON
64. Local Input Terminals [LOCAL INPUT]
(VM-3240E only)
Local broadcast can be made when this terminal
is used in conjunction with the Control Input
terminals (55).
For details, refer to "6. SYSTEM SETTINGS; 6.8.
Local Input Setting" in the separate software
instruction manual.).
65. Local Input Volume Control
(VM-3240E only)
Adjusts the input volume of the equipment
connected to the Local Input terminal (64).
66. LAN Connector [LAN]
(VM-3240E only)
Not used.
67. VM Link In Connector [VM LINK IN]
(VM-3240E only)
Connect this connector to the VM-3240VA’s VM
LINK OUT connector. When using two or more
VM-3240Es, connect this connector to other VM-
3240E’s VM LINK OUT.
68. Local Remote Microphone Link Connector
[LOCAL RM LINK IN]
(VM-3240E only)
Not used.
69. PA Link Connector [PA LINK]
Not used.