36
Communications Failure indicator
[RM-200M]
The Communications Failure indicator flashes yellow.
Equipment Operation Upon Failure Detection
A failure has occurred in communications between the RM-200M and the VM-3240VA.
The previous status is automatically restored if communications return to normal.
9.4.2. Failure acknowledgment
Perform failure acknowledgment at the VM-3240VA or by use of the control input.
Acknowledging a failure causes all currently sounding buzzers to stop. At the same time, the flashing yellow
Failure indicator on the VM-3240VA will switch to steady on mode.
If the failure having been already acknowledged still remains more than 24 hours, the buzzer sound is
automatically restarted.
Note
Only the Failure indicator is switched from flashing to steady on mode when failures are acknowledged.
The Communications Failure indicator that flashes when a communications-related failure occurs will remain
flashing.
[Acknowledging failures at the VM-3240VA]
Press the [OK] key.
[OK] key