General Run and Transport Problems
Problem Possible Causes
Engine kills when the functional control lever is in the
MOW or TRANSPORT position with the operator in the
seat.
Operator is sitting too far forward on the seat (seat
switch not depressed).
Parking brake is engaged.
Parking brake switch is out of adjustment or is faulty.
Parking brake switch wiring is loose, corroded or
damaged.
Seat switch is faulty.
Seat switch wiring is loose, corroded or damaged.
Battery does not charge. Wiring to the charging circuit components is loose,
corroded or damaged (see electrical schematic in
Chapter 10 -- Foldout Drawings).
The engine alternator belt is loose or damaged
(Greensmaster 3400).
Voltage regulator is loose or not grounded to engine
(Greensmaster 3300).
Charge circuit relay or circuit wiring is faulty
(Greensmaster 3300).
Alternator fusible link in the fusible link harness is
faulty.
Battery is faulty.
Alternator/voltage regulator is faulty.
Engine kills during operation (operator sitting on seat). Operator moved too far forward on the seat (seat
switch not depressed).
The parking brake was engaged or the parking brake
sensor is out of adjustment or faulty.
The seat switch or circuit wiring is faulty.
Wiring to run circuit components is loose, corroded or
damaged (see electrical schematic in Chapter 10 --
Foldout Drawings).