EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Troubleshooting; General Hydraulic System Problems

Toro Greensmaster TriFlex 3400
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Greensmaster 3300/3400Hydraulic System Page 5 -- 26
Troubleshooting
The charts that follow contain information to assist in
troubleshooting. There may possibly be more than one
cause for a machine malfunction.
Refer to the Testing section of this Chapter for precau-
tions and specific test procedures.
General Hydraulic System Problems
Problem Possible Cause
Hydraulic oil leaks from system. Fitting(s), hose(s) or tube(s) are loose or damaged.
O--ring(s) or seal(s) are missing or damaged.
Hydraulic fluid foams. Oil level in reservoir is low.
Hydraulic system has wrong type of oil.
The pump suction line has an air leak.
Hydraulic system operates hot. Oil level in reservoir is low or inlet filter is loose or c logged.
Oil is contaminated or too light.
Parking brake is applied or incorrectly adjusted.
Piston pump by--pass valve is open or defective.
Working load of machine may require use of oil cooler.
Oil cooler (if installed) is damaged or plugged.
Oil cooler (if installed) by--pass relief is stuck open or air flow is ob-
structed.
Charge pressure is low.
Wheel motor(s) or reel motor(s) are worn or damaged.
Piston pump is w orn or damaged (see Piston (Traction) Pump Flow
Test in the Testing section of this chapter).