PrimingtheHydraulicPump(continued)
Note:AbluewireconnectstothestartermotorsolenoidB+terminal(Figure
64).Itisnecessarytoremovethisbluewirefromthesolenoidterminalfor
hydraulicpumppriming.
4.Connecttheremotestarterswitchelectricalleadstothestartermotor
solenoidB+terminalandpositivepostofthebattery.
5.Engagetheremotestarterswitchandcrankthestarterfor30secondsto
primethehydraulicpumps.Waitfor30secondstoallowthestartermotorand
startersolenoidtocool.Repeatthecrankingprocedureforthesecondtime.
6.Disconnecttheremotestarterswitchleadsfromthestartermotorsolenoid
terminalandpositivepostofthebattery.
7.Connectthewireharnesselectricalconnectortothefuelsolenoidterminal.
ProLineH800
Page5–71
HydraulicSystem:ServiceandRepairs
19241SLRevB