TestingtheChargingSystem
Thisisasimpletestthatdeterminesifachargingsystemisfunctioning.Ittells
youifthechargingsystemhasanoutput,butnotitscapacity.
Toolrequired:DigitalmultimetertosetDCvolts.
Testinstructions:Connectthepositive(+)multimeterleadtothepositive
batterypostandnegative(-)multimeterleadtothenegativebatterypost.Keep
thetestleadsconnectedtothebatterypostsandrecordthebatteryvoltage.
Note:Whenstartingtheengine,thebatteryvoltagedropsandthenmust
increaseoncetheengineisrunning.
Note:Dependingupontheconditionofthebatterychargeandbattery
temperature,thebatteryvoltageincreasesatdifferentratesasthebattery
charges.
Starttheengineandrunitathigh-idlespeed.Allowthebatterytochargefora
minimumtimeof3minutes.Recordthebatteryvoltage.
Note:Afterrunningtheengineforaminimumtimeof3minutes,thebattery
voltagemustbeminimum0.50Vhigherthanthatoftheinitialbatteryvoltage.
RefertotheBatteryVoltageT able(page6–4)foranexampleofacharging
systemthatisfunctioning.
BatteryVoltageTable
Atleast0.50Vovertheinitialbatteryvoltage
Initialbatteryvoltage=12.30V
Batteryvoltageafter3minutescharge
=12.85V
Difference
=+0.55V
ElectricalSystem:ElectricalSystemQuickChecks
Page6–4
ProLineH800