TestProcedure(continued)
CAUTION
Beforeopeningthehydraulicsystem,operateallthehydraulic
controlstoreleasesystempressureandavoidinjuryfromthe
pressurizedhydraulicuid;refertoReleasingPressurefromthe
HydraulicSystem(page6–8).
2.ReadallWarning,Cautions,andprecautionslistedatthebeginningofthis
section.
3.Liftandsupporttheoperatorseatandremovetheoorplatetogetaccessto
thehydraulicpump.
g217942
Figure141
1.Gearpump(P4)
2.Hydraulichose
4.Cleanthehydraulichoseendandthepumpttingattheoutletofpump(P4)
(Figure141).
IMPORTANT
Ensurethattheuidowindicatorarrowontheowgaugeis
showingthattheuidwillowfromthepump(P4),throughthe
tester,andtotheliftcontrolmanifold.
5.Connectthetesterinlettothepumptting,andconnectthetesteroutletto
thedisconnectedhydraulichose.Ensurethattheowcontrolvalveontester
isfullyopen.
6.Starttheengineandrunitatlow-idlespeed.Checkforhydraulic-uidleaks
fromthetestconnectionsandcorrectbeforecontinuingthetest.
7.Withtheenginerunning,presstheenginespeedswitchtofullspeed(3,005
to3,055rpm)position.UsetheInfoCentertocheckthattheenginespeedis
correct.
8.VerifythepumpowatNoLoadasfollows:
Recordthetesterpressureandowreadingsatnoload.Unrestrictedpump
outputshouldbeapproximately11.4L/minute(3gallons/minute).