EasyManua.ls Logo

Toro reelmaster 5410 series - Page 373

Toro reelmaster 5410 series
662 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MachineFaults(continued)
3.AllowthemachinetoremainOFFforatleast1minute.
4.Restarttheengineandcheckthemachineoperation.
5.Ifafaultcontinuestooccur,furthersystemevaluationandpossible
componentrepairorreplacementwillbenecessary.
Toviewadescriptionofafaultthathasoccurredsincethefaultswerelast
clearedfromtheInfoCenter,pressthedownbutton(asindicatedbytheat
thebottomofthescreen)tohighlightthedesiredfault,thenpresstheleft/right
button(asindicatedbythe
).
Toreturntothepreviousscreen,pressthemenu/backbutton(asindicatedby
the
atthebottomofthescreen).
ClearSystemFaults(PINrequired)Ifthecorrectpasscode(PIN)hasbeen
entered(refertotheProtectedMenusintheSettingsScreen(page7–21))the
InfoCenterfaultlogcanbeclearedbyselectingClearSystemFaults.Thecleared
faultswillberemovedfromtheInfoCenterlistbutwillberetainedintheTEC
memory.ContactyourT oroDistributortoviewfaultsstoredintheTECmemory.
EngineFaults
g187359
Figure208
1.Enginefault(Yanmardieselengine)
YanmarDieselEnginesIfanenginefaultoccursduringmachineoperation,the
faultindicatorwillilluminateandthefaultwillbedisplayedontheInfoCenterto
notifytheoperator(Figure208).Theenginefaultwillcontinuetoappearuntil
theoffendingconditioniscorrected.Oncetheoffendingconditionhasbeen
corrected,theenginefaultwillberetainedintheengineelectroniccontrolunit
(ECU)andcanonlybeviewedusingtheenginediagnostictool.Enginefaults
arenotstoredintheToroElectronicController(TEC)sothattheenginefault
historycannotbeviewedusingtheInfoCenterfaultsscreen.
Note:RefertotheYanmarEngineServiceManualandTroubleshootingManual
foradditionalinformation.
Reelmaster
®
5410/5510/5610Series
Page7–17
ElectricalSystem:InfoCenterDisplay
15216SLRevC

Table of Contents

Related product manuals