5.4.3 STRIP SENSOR ADJUST COMMAND [ESC] AH
Function Sets the sensor threshold value to switch the mode between strip and batch.
Format [ESC] AH; a [LF] [NUL]
Term a: Setting
0: Operation in conformance with the strip sensor
1: Operation in conformance with the strip sensor
2: Fixed at the batch mode
3: Fixed at the strip mode
4: Reserved
Notes
(1) The set parameter is backed up and kept until a parameter is set using this command.
When the power is turned on, the backed up value is retrieved and set
(2) “0: Operation in conformance with the strip sensor” has been set as the default at the time
of shipment from the factory.
(3) When either “2: Fixed at the batch mode” or “3: Fixed at the strip mode” for parameter “a,”
is selected, the printer operates in the specified mode, without automatically switching
between the batch and strip modes.
(4) When “4: Reserved” for parameter “a” is selected, this command is ignored.