SELF-DIAGNOSIS MODES
5 - 36
Separation pad
(1st drawer)
6406-0,1,2,8 6407 < Default values>
Sub-codes 0, 2, 8: 0
Sub-code1: 80,000
Separation pad
2nd drawer (PFU)
6408-0,1,2,8 6409 < Default values>
Sub-codes 0, 2, 8: 0
Sub-code 1: 80,000
Separation roller
3rd drawer (PFP)
6412-0,1,2,8 6413 < Default values>
Sub-codes 0, 2, 8: 0
Sub-code 1: 80,000
Separation roller
4th drawer (PFP)
6414-0,1,2,8 6415 < Default values>
Sub-codes 0, 2, 8: 0
Sub-code 1: 80,000
Separation pad
(Bypass unit)
6416-0,1,2,8 6417 < Default values>
Sub-codes 0, 2, 8: 0
Sub-code 1: 80,000
Feed roller
(Bypass unit)
6424-0,1,2,8 6425 < Default values>
Sub-codes 0, 2, 8: 0
Sub-code1: 80,000
Recovery blade 6436-0 to 8 6437 < Default values>
Sub-codes 0, 2, 3, 5, 6, 7, 8: 0
Sub-code 1: 165,000
Sub-code 4: 345,000
Items
PM management
setting
<Procedure 4>
*Indicated in 8 digits
Date of previous
replacement
<Procedure 2>
Remarks