Adjustment Mode (05) Codes
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptabl
e value
SRAM Contents
Proce
dure
20L
/
23L /
25L
20H
/
23H /
25H
05 Adjustment
mode
Process Developm
ent
2000 - Auto toner sensor auto
adjustment (heater ON)
- - - As the value increases, the sensor output increases
correspondingly.
17
YY
05 Adjustment
mode
Process Developm
ent
2001 - Auto toner sensor
manual adjustment
(heater ON)
165 0-255 M Corrects the control value of the auto-toner sensor setup in
05-2000.
* Selection is disable when developer unit is not installed.
3
YY
05 Adjustment
mode
Process Developm
ent
2020 - Developer bias DC
output adjustment
131 0-255 M As the value increases, the transformer output increases
correspondingly.
3
YY
05 Adjustment
mode
Process Charger 2040 - Main charger grid bias
output adjustment
123 0-255 M As the value increases, the transformer output increases
correspondingly.
3
YY
05 Adjustment
mode
Process Transfer 2052 - Transfer transformer
DC output adjustment
(Center)
138 78-255 M As the value increases, the transformer output increases
correspondingly. (Main motor, main charger, discharge
LED, transfer ON)
3
YY
05 Adjustment
mode
Process Separation 2078 - Separation transformer
DC output adjustment
(Center)
52 0-255 M As the value increases, the transformer output increases
correspondingly. (Main motor, discharge LED, separation
DC / separation AC ON)
3
YY
05 Adjustment
mode
Process Transfer 2083 - Transfer cleaning bias
adjustment (Positive)
118 78-255 M The larger the setting value is, the higher the value of the
current (more positive) is.
3
YY
05 Adjustment
mode
Process Transfer 2084 - Transfer cleaning bias
adjustment (Negative)
66 0-77 M The larger the setting value is, the higher the value of the
current (more negative) is.
3
YY
05 Adjustment
mode
Process Image
control
2192 - Relative humidity latest
value
50 0-100 M Displays the humidity value detected by
temperature/humidity sensor.
2
YY
05 Adjustment
mode
Process Image
control
2194 - Temperature latest
value
25 0-50 M Displays the temperature value detected by
temperature/humidity sensor.
2
YY
05 Adjustment
mode
Process Image
control
2196 - Drum temperature
latest value
25 0-100 M (Unit: degrees C) 2
YY
05 Adjustment
mode
Process Image
control
2250 - Laser power
adjustment
118 0-255 M When the value increases, the laser output increases
correspondingly.
3
YY
05 Adjustment
mode
Process Image
control
2382 - Reverse time of the
drum
13 0-255 M 1
YY
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-5
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)

Table of Contents

Related product manuals