ADJUSTMENT
3 - 62
Note: Note:
Do not input more than 8 for acceptable value. (If a number from 9 to 255 is input, it is processed
as 8.)
Relation between adjustment value and changing amount
* CW: Clockwise
CCW: Counter Clockwise
Code to be used for the adjustment
Adjustment mode (05)
Code Classifi-
cation
Items Function Default
<Accept-
able
value>
RAM Contents Proce-
dure
499 Develop
-ment
Black developer unit
lift up/down timing
adjustment
ALL 4
<0-255>
M Changes the lift up/down
timing of the black devel-
oper unit when a CEB0
error occurs.
1
Adjustment
value
Changing amount for default value
(Turning degree of black developer unit lift up/down lever)
0 Turning 32 degrees CW (approx. 12 mm in the lever circumference)
1 Turning 24 degrees CW (approx. 9 mm in the lever circumference)
2 Turning 16 degrees CW (approx. 6 mm in the lever circumference)
3 Turning 8 degrees CW (approx. 3 mm in the lever circumference)
4 Default value
5 Turning 8 degrees CCW (approx. 3 mm in the lever circumference)
6 Turning 16 degrees CCW (approx. 6 mm in the lever circumference)
7 Turning 24 degrees CCW (approx. 9 mm in the lever circumference)
8 Turning 32 degrees CCW (approx. 12 mm in the lever circumference)