© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO281c/351c/451c
TROUBLESHOOTING
5 - 89
5
[CE50] Temperature/humidity sensor abnormality
[CE90] Drum thermistor abnormality
Is the connector CN333 on the LGC board or the connector of the temperature/humidity sen-
sor disconnected?
Is the harness between the LGC board and the temperature/humidity sensor disconnected ?
È YESÆ Connect the connector securely. Replace the harness.
NO
1) Replace the temperature/humidity sensor.
2) Replace the LGC board.
Is the connector CN333 on the LGC board, or the connector of the drum thermistor discon-
nected?
Is the harness between the LGC board and the drum thermistor disconnected?
È YESÆ Connect the connector securely. Replace the harness.
NO
1) Replace the drum thermistor.
2) Replace the LGC board.