EasyManua.ls Logo

Toshiba e-studio281c - 3.13.3 Adjusting the overlap of the sensor flag

Toshiba e-studio281c
678 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO281c/351c/451c
ADJUSTMENT
3 - 81
3
3.13.3 Adjusting the overlap of the sensor flag
If the overlap between the sensor and the flag is wrong for some reason, perform the following adjust-
ment.
(1) Remove the processing tray unit.
(2) Loosen the mounting screw of the front/rear
jogging plate adjusting plate; then, move the
adjusting plate to the left and the right.
Fig. 3-73
(3) Tighten the screw so that the overlap
between the flag of the front/rear jogging
rack plate and the sensor is 1.5 mm to 2.0
mm.
Fig. 3-74
Jogging plate
adjusting plate
Screw
Adjusting plate
Screw
Jogging plate
adjusting plate
Adjusting plate
Sensor Sensor flag
1.5 mm to 2.0 mm