Func. Name Descriptions
Range of
Setting
Unit
Factory
Setting
Note
F5.26
Multi-function
Output Setting
of Ta/Tc
Terminals
0: Disable
±1: Running detection
±2: Constant speed detection
±3: Zero speed detection
±4: Frequency detection
±5: Overload detection(OLO)
±6: Stall prevention detection
±7: Low voltage detection(LE)
±8: Braking transistor is active
detection(db)
±9: Restart after instantaneous
power failure detection
±10: Restart after fault condition
detection
±11: Fault detection
±12: Start detection of sequential
operation control
±13: One complete operation sector
detection of sequential operation
control
±14: One complete operation cycle
detection of sequential operation
control
±15: Pause command detection of
sequential operation control
±16: Detection of counter value1
±17: Detection of counter value2
±18: Reverse detection
±19: NTC temperature warning
detection (OHt)
±20: Fan operation detection
±21: PTC temperature warning
detection (OH1)
-21~+21
*Note 7
11
F5.30
UP/DOWN
Memory
Selection
0: Erase UP/DOWN frequency
command when power off
1: Store UP/DOWN frequency
command when power off
0, 1 0
*Note 9
F5.31
UP/DOWN
Frequency
Calibration
0: 0.01Hz
1~8: ×0.05Hz
9: 0.5Hz
10~250: ×0.1Hz
0~250 0
*Note 9
The color as means functions can be set during the operation.