h. F1.00 = 8
(I) Start command and the motor rotating direction are controlled by communication.
(II) Forward and reverse commands are disabled.
i. F1.00 = 9
(I) Multi-function input terminals(X1~X4) define as the reverse command and the
motor runs at the reverse direction (counterclockwise).
(II) Start command is given by communication control, and the motor rotating
direction is defined by reverse command (defined by multi-function input
terminals).
j. F1.00 = 10
(I) Multi-function input terminals(X1~X4) define as the reverse command and the
motor runs at the reverse direction (counterclockwise).
(II) Start command is given by forward command (defined by multi-function input
terminals) and the motor rotating direction is controlled by communication.
(III) Forward and reverse commands are disabled.
k. F1.00 = 11
(I) Start command by “RUN” key of the operation panel and the motor rotating
direction by communication.
(II) Forward and reverse commands are disabled.
※F1.00 = 0 or 2
If the forward and reverse commands are active at the same time, the operation
panel will display “------“ along with inter-flashing display value at monitor mode.
If the forward and reverse commands are set (closed) simultaneously, the
operation panel will be flashing to display “dtF” in the monitor mode.
※When the motor rotation direction is set to reverse, the output frequency will
display “-“ and the reversed indicator will ON.
【F1.01】 Primary Frequency Command Selection
a. F1.01 = 0
The frequency is controlled by analog input terminal (select the analog input
source:
“Pot knob”, AI by defining function F1.03)
(I)
“Pot knob”:
For the gain and bias ranges of frequency settings, please refer to functions
F5.03 and F5.04.
(II) AI-GND:
For the gain and bias ranges of frequency settings, please refer to functions
F5.05 and F5.06.
Select the input mode by JP1
JP1I mode:
The range of input current is 4~20mA or 0~20mA (selection by function F5.02)
JP1V mode:
The range of input voltage is 2~10V or 0~10V (selection by function F5.02)
42