ERROR! INCORRECT BASEBOARD ID
This error occurs if the ID stored in the base unit does not match the
ID stored in the control unit.
Solution: Make sure the control unit is the correct unit for a
particular base unit.
INVALID DEPTH – CHECK SOURCE ROD
This error occurs when the source rod is not at a valid depth when
starting a measurement.
Solution: Check source rod position to ensure it is at a valid depth
when starting a measurement. Recalibrate depth strip. Call the
nearest Troxler Service Center.
KEYPAD ERROR!
This error is reported after the power-up self-test if a stuck key is
detected.
Solution: Clear the keypad of any objects pressing keys on
powerup.
LCD ERROR!
During the Liquid Crystal Display (LCD) test, a sequence of
characters is written to the LCD and is then read back. This message
occurs if a character read back does not match the character written
out.
Solution: Call the nearest Troxler Service Center.