Appendix C–14
ERROR MESSAGES
BATTERIES TOO LOW! GAUGE IS TURNING OFF IN XXX
SECONDS
This error occurs when the following three items are all true: the
charger is not connected, the NiCad batteries are low, and the
alkaline batteries need replacing.
Solution: Charge the NiCad batteries and replace the alkaline
batteries.
DIVIDE BY ZERO ERROR!
This error occurs when attempting to perform division by zero.
Solution: Check for incorrect measurement depth, calibration
constants, standard count, counts, offsets, and special calibrations.
Identify and correct the problem.
ERROR! BASEBOARD NOT CONNECTED
This error occurs when the control unit does not detect a base unit.
Solution: Unscrew the four captive screws on the control panel and
make sure the ribbon cable connecting the control unit with the base
unit is seated properly.
ERROR! GAUGE MUST BE IN THIN LAYER MODE
This error occurs when attempting to enable a thin layer special
calibration when in Soil or Asphalt mode.
Solution: To enable a thin layer special calibration, change to the
Thin Layer mode. To enable special calibration in Soil or Asphalt
mode, select the special calibration for the selected mode.