STORING DATA
The Model 3450 can store up to 1,000 readings. The gauge stores
readings under the project name that has been enabled. The gauge
can store up to 620 readings per project. The operator can retrieve,
print, and upload stored project data. For more information on
selecting a project, see page 5–5.
When storing test results, the gauge can also store project notes or
information required on FHWA projects. The gauge stores this extra
project information with the project data. By default, the gauge
allows the operator to enter project notes. To edit project notes later,
use the Edit Notes feature described on the following page.
STORE DATA
After taking a measurement, the operator can store the data in the
selected project by pressing the
〈STORE〉 key when the gauge
displays the Ready screen. The gauge requests the station number as
shown below. It displays the last station number on the third line.
Enter the station number (up to six numbers) and press 〈ENTER〉.
The gauge prompts the operator to enter additional project
information. Press the
〈SHIFT〉 key to access the alphabetic
characters and enter the information. If Full Store mode (page
5–12)
is enabled, the 3450 gauge prompts the operator for more in-depth
test data. The gauge stores the data with any additional project
information under the selected project and returns to the Ready
screen.
_ _ _ _ _ _
Last Station: 0
ENTER When Done