BATTERY STATUS
The Battery Status option displays the charge status of the NiCad
batteries and the voltage of the NiCad and alkaline batteries. The
Battery Status option is a Special function under Gauge Setup. To
access the Gauge Setup menu, press the
〈SPECIAL〉 key, then press
〈4〉.
To scroll through the Gauge Setup menu, use the arrow keys. To
select Battery Status, press
〈7〉.
The first line shows the NiCad charger voltage and status. The
second line shows the NiCad battery voltage and status. The third
and fourth lines show the voltage and status for the two sets of
alkaline batteries. The minimum requirements for battery operation
are as follows:
Minimum
NiCad batteries 4.0 V
Alkaline batteries 1 (ALK1) 3.0 V
Alkaline batteries 2 (ALK2) 3.5 V
If the NiCad batteries are below their minimum voltage, re-charge
them. If either ALK1 or ALK2 is below its minimum voltage,
replace both sets of batteries.
Return to the Gauge Setup menu by pressing the 〈ENTER〉 key.
Return to the Ready screen by pressing the
〈ESC〉 key.
2-
Print Set-Up
3-
Depth Indicator
4- Set Beeper Level
Nicad: 4.5V- In Use
Alk 1: 4.3V- Ready
Alk 2: 4.5V- Ready