UNPACKING AND INSPECTION
Troxler recommends that the operator wear a dosimeter while
working with the gauge. Upon receipt of the gauge from the factory,
perform a complete inspection and inventory. If the shipping case
and/or any other part or accessory appears damaged, notify the
carrier and your Troxler Representative immediately.
For shipping to another location or back to the factory, save the box
and any packing material. For shipping instructions and regulations,
please see Appendix D.
Check the shipping case for the following:
♦
Model 3450 Gauge
♦
Reference Standard Block
♦
Drill Rod
♦
Scraper Plate/Drill Rod Guide
♦
Extraction Tool
♦
AC Charger
♦
DC Adapter (for a vehicle cigarette lighter)
♦
Manual of Operation and Instruction
♦
Gauge Warranty
♦
Source Certificate
♦
Transportation Guide (This guide refers to U.S. standards. All
other countries please refer to local regulations. In the absence
of local regulations, please use this guide as a reference only)
NOTE
Charge the batteries for four hours prior to initial use.
Lift the gauge from the transport case and inspect the outside
surface for damage. Check the lock on the source rod handle and
make sure the keys fit. Remove the lock, release the trigger, and
check the source rod operation. It should move up and down with
little effort. Return the gauge to the transport case.