NOTE
Prior to countdown, the gauge may display Please Wait
for five seconds. This occurs if the baseboard electronics
require warmup prior to starting the measurement.
✓
The gauge will display the time remaining while taking a
measurement.
✓
After the count time, the gauge displays the measurement
results.
NOTE
This is one of three screens that may appear, depending
on the previous selections.
where: %PR = percent Proctor
DD = dry density
WD = wet density
M = moisture
%M = percent moisture
If a project is enabled (see the Handling Project Data section on
page 5–5),
press the 〈STORE〉 key to store the measurements.
To scroll through the results, use the arrow keys. Return to the
Ready screen by pressing the
〈ESC〉 key, or press the 〈START〉
key to make another measurement.
✓
Lift the gauge from the test site by the source rod handle. This
returns the source rod to the SAFE position. When not taking
readings, always keep the source rod in the SAFE position.
pcf