Specifications 7-3
Measurement
1
High Flow Module (4081)
2
Low Flow Module (4082)
3
Low Pressures
P PIP P
EEP
P
MAP
P
MIN
P
P
PLAT
Range
-25 to 150.0 cmH
2
O
Not available
Accuracy
±0.5% of reading or ± 0.15 cmH
2
O,
whichever is greater
Not available
Leak Rate
LR
Range
±30 cmH2O/s
Not available
Accuracy
±0.5% of reading or ± 0.2 cmH
2
O/s,
whichever is greater
Not available
High Pressure
P
High
Range
-10 to 150.0 psig
Not available
Accuracy
±1% of reading or 0.1 psi, whichever
is greater
Not available
Absolute Pressure
P
ABS
Range
50 to 200 kPa
50 to 200 kPa
Accuracy
±0.7% kPa
±0.7% kPa
Oxygen Concentration
O
2
Range
21 to 100%
Not available
Accuracy
2% concentration
Not available
Temperature
T
Range
5 to 40 °C
5 to 40 °C
Accuracy
±1 °C when flow rate is above
2 liters/min
±1 °C when flow rate is above
2 liters/min
Static Compliance
C
Stat
Range
5
0.01 to 1000 mBar/ml
Not available
Accuracy
3% or 1 mBar/ml,
whichever is greater
Not available
NOTES:
1 Standard conditions are defined as 21.1 °C (70 °F) and 101.3 kPa (14.7 psia). Flow and volume accuracy are
applicable at these standard conditions. SLPM = standard liters per minute
2 For the High Flow Module, the temperature of the gas and the ambient air must be within ±10 °C (±18 °F) of
each other and the gas must be less than 30% relative humidity at 21.1 °C (70 °F).
3 For the Low Flow Module, the temperature of the gas and the ambient air must be within ±5 °C (±9 °F) of
each other and the gas must be less than 30% relative humidity at 21.1 °C (70 °F).
4 Flow and volume accuracies are stated at 21.1 °C (70 °F), 101.3 kPa (14.7 psia), and
<= 30% RH
Add an additional ±0.075% of reading per 1 °C (1.8 °F) away from 21.1 °C (70 °F)
Add an additional ±0.022% of reading per 1.03 kPa (0.15 psia) below 101.3 kPa (14.7 psia)
Add an additional ±0.07% of reading per 1% relative humidity above 30% relative humidity
5 Must develop at least 7 cmH
2
O of pressure to obtain a valid static compliance measurement.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSI Instruments Certifier Plus and is the answer not in the manual?

TSI Instruments Certifier Plus Specifications

General IconGeneral
BrandTSI Instruments
ModelCertifier Plus
CategoryTest Equipment
LanguageEnglish

Related product manuals