Tyco Electronics Galaxy SC Controller J85501F-1
Issue 13 February 2001 T1.317 Error Messages Appendix C - 5
-328,FEATURE DISABLED
An attempt was made to activate a feature that has been disabled. Check
the feature’s software and hardware DIP switch settings.
-329,INDEPENDENT CTLR NOT AVAILABLE
An attempt was made to access a feature that requires the independent
controller support.
-331,NOT OPERATE ATTRIBUTE
An attempt was made to use the OPE command on an attribute that
cannot be changed using the OPE command. Try using the CHA
command instead.
-332,COMMAND NOT ALLOWED
Because of the serious affect that they may have, some commands are
not allowed. Some examples of commands that are not allowed are:
CLH Clear all event histories
OPE REC,STT=STANDBY- Set all rectifiers to standby at once
-334,PORT CONFIGURATION DISABLED
Access port configuration is disabled. Check the serial port
configuration attribute in the PS1 object and the MODEM/AUX/
LOCAL PORT CONFIG DIP switch setting on SW203 on the
intelligent controller.
-336,PORT IS BUSY
An attempt was made to pass-thru to a data switch port already in use.
-338,CONNECTION FAILED
A connection failed during an attempt to pass-thru on a data switch port.
-339,BOARD MISSING
A command was executed that requires the presence of a missing circuit
pack. For example, this error will be reported if an attempt is made to
pass-thru on the data switch without a data switch circuit pack.
-340, EQUIPMENT NOT DETECTED
This error will occur if an attempt is made to pass-thru on the data switch
when the connected equipment is not sensed via the DSR signal.
-341,ALARM ACTIVE
The command could not be executed due to active alarms in the system.
-342, OBJECT IS LOCKED
An attempt was made to delete a remote peripheral monitor module that