Important:
- When in the “component tests” menu the machine goes into the “test” mode; all the keyboards are
disabled and their lights go off (BGX and BST), the heating of the groups and the steam is disabled
- The group selected is illuminated in red
- During an operation the group selected flashes red
- When we exit from the “component tests” menu the machine returns to normal operation.
water doser DOE over
10sec
Press= hot water
solenoid valve (EVE)
on for 10 sec (see
detail)
display
from 10 sec.
It is possible to stop the
cycle by pressing the
key again
30/01/13)
The display increments
the seconds and the
pulses
, and holds the
display at the end of
the cycle. (modif. of
30/01/13)