Note: the coffee machine is only usable when the badge contact is closed.
To simulate the presence of the badge it is possible to connect points 33 and 35 of connector CN7 of
the main interface.
For the machine to work without the I/O interface, either connect points 2 and 3 of cable part no:
NZ8018 or make a strap between points 2 and 3 of connector CN13 (red).
IMPORTANT: THE CONNECTION CAN ONLY BE MADE WITH MACHINES FITTED WITH
VERSION V1.0 OR HIGHER.
To configure the machine in a computer system, with the technician’s key activate the desired mode in
the maintenance / CIM menu and fit or remove a JP3 strap of the interface (see below) and position
strap
of the
on
12V.
JP3 STRAP: allows configuration in Credit / Debit (CD) or Debit / Credit (DC).
To configure the interface in DC, fit strap JP3.
To configure the interface in CD, remove strap JP3.
SETTINGS:
-1200 bit / sec.
- Parity EVEN