47
OPERATING CONTROLS AND FUNCTIONS
METERS, INDICATORS AND LAMPS (cont’d)
REPROGRAMMING AFHS BUTTONS
NOTE: PB 1 thru 6 must be set sequentially, with 1 being the lowest
rack level, 2 the next etc. If the racking is changed by adding a lower
rack level the stops will need to reset. Trying to program a higher PB,
i.e. setting PB 6 at a lower level than PB 1 will cause the following
warning screen on the meter panel display.
1. Press and hold PB until the LED on the
switch turns on.
2. Press and hold the preset pushbutton to be
reprogrammed until the LED on the switch turns
off.
3. Press and release PB .
The LED on PB will go out and the preset
button LED will ash and go out.
4. Refer to the AFHS Programming section to program for new
rack height.
Turning Lift Limit Off
1. Raise the mast above free lift.
2. Select which lift limit you wish to turn off, A or B. If the A/B
switch LED is off you will be turning off the A rack lift limit. If the
A/B switch LED is on, you will be turning off the rack B lift limit.
3. Press and hold PB until the LED on the switch turns on.
4. If the LED on the lift limit switch is not on, press
and release the lift limit switch.
5. Press and hold the lift limit switch until the LED
goes out.
6. Press and release PB .
7. The chosen lift limit switch is now active.