67
GENERAL CARE AND MAINTENANCE
CHARGING PREPARATIONS
1. Move the forklift to the charging area
and park it.
2. Check the battery uid level. Replenish
the battery uid to the specied level
with distilled water as required.
3. Check that the circuit breaker on the
AC power supply side is OFF.
WARNING
!
!
• During battery charging, large quantities of highly-explosive
hydrogen gas may be released from the battery. To minimize
the danger of an explosion, battery charging should be
performed in a well-ventilated area protected from direct
sunlight. Remove all objects that might ignite the gas from
the immediate area before beginning charging.
NOTE:
Transformer tap selection is required before beginning
charging. Measure the charger power supply voltage. Select the
appropriate transformer tap.
Selection of the wrong tap will result in battery over-charging
or under-charging. Contact your Local Authorized Dealer if you
require more detailed information.
OFF
HOW TO CHARGE BATTERY (OFF-FORKLIFT TYPE)
Charge the battery according to the manual supplied with the charger
being used.
EXAMPLE ONLY