EasyManua.ls Logo

UniCarriers SRX Series - Page 80

UniCarriers SRX Series
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78
MAINTENANCE AND INSPECTION (cont’d)
FORK REPAIR
Repair - Only the manufacturer of the fork or an expert of equal
competence shall decide if a fork may be repaired for continued use,
and the repairs shall only be carried out by such parties. It is not
recommended that surface cracks or wear be repaired by welding.
When repairs necessitating resetting are required, the fork shall
subsequently be subjected to an appropriate heat treatment, as
necessary.
CHECKING HORN
Check the horn for proper operation.
CHECKING LIGHTS (IF EqUIPPED)
Mark sure that lights illuminate when switches are placed into the "ON"
position.
CHECKING CARGO-HANDLING CONTROL ON mULTI-
FUNCTION HANDLE
Check the cargo-handling control for proper operation. Ensure that the
forks lift, lower, and tilt forward and backward properly.
CHECKING SAFETY START SYSTEm OPERATION
If the ignition switch is turned to the "ON" position again after it has
been turned to the "OFF" position with the multi-function handle set in
the forward or reverse position, make sure that the traction circuit will
not operate and the forklift will not start. After making sure of the above,
return the handle to the neutral position. Then make sure the traction
circuit operates and the forklift starts when the ignition switch is turned
"ON" and the handle is set in the forward or reverse position. If either
tests do not function contact your Local Authorized Dealer.
GENERAL CARE AND MAINTENANCE
CHECKING bRAKE PEDAL OPERATION
Depress brake
FUSES
WARNING
!
!
Remove all jewelry.
Make sure the ignition switch is "OFF" and disconnect the
battery before changing any components or disconnecting
any wiring. This will reduce the possibility of damage to the
controller system.\
Do not use fuses that are rated higher or lower than shown
on the fuse label.
Fuse 40 A (for EPS)
Fuse 500 A (for travel/hydraulic)
Tube fuse 7A
Remove the fuse box cover and visually
check if the fuse is blown. Before
replacing any malfunctioning fuse,
check and correct the cause of the
malfunction. Use a fuse of the specied
rating which is clearly shown on the
label.

Table of Contents