UniPOS IFS7002 two signal loops
Instruction Manual Page 11
Revision 11/01.17 Of 145
Entering inspection time period (see section 8.3.1);
Forced proceeding from phase Fire condition stage I to phase Fire condition stage II (see
section 8.3.3);
Suppressing the local sounder (see sections 8.3.2 and 9.3.1);
Displaying text messages from the inputs (see section 12.2.4);
Displaying program data for the fire control panel (see sections 12.2.6 to 12.2.9 and
12.2.11);
Displaying the status of the addressable devices in the loops (see section 12.2.10);
Displaying the archive (see section 12.2.12).
All light indicators are visible.
6.1.2. Access Level 2
The personnel in charge of the fire protection have access to level 2; they shall be authorized and
trained to operate the fire control panel in the following conditions:
Duty Mode;
Fire condition;
Fault condition;
Disabled component;
Information and adjustment.
To enter Access level 2 use your password.
The following features of the fire control panel are accessible:
All features accessible at Level 1;
Switching off the outputs, activated upon fire condition (see section 8.3.4);
Exit of Fire condition (see section 8.3.5);
System functions of the fire control panel (see section 12.3).
6.1.3. Access Level 3
Accessible for personnel trained and authorized for:
Reconfiguration of specific data of the protected site or of the fire control panel saved
in the memory;
Maintenance of the fire control panel.
This level has two sublevels of access - 3A and 3B.
Level 3, sublevel 3A, is accessed through a password entered at Access level 2. At this sublevel
the functions for reconfiguration of specific data for the protected site or the fire control panel are
accessible (see section 13).
Level 3, sublevel 3B is accessed when the fire control panel is opened. The following features are
accessible:
Replacing a burnt fuse;
Connecting fire alarm loops and executive devices.
6.1.4. Access Level 4
Accessible for personnel trained and authorized by the Producer to repair the fire control panel
and to modify the software. Special means are required to enter this level.
6.2. Indications and buttons for control
Table 1 gives detail description of the indications for each status, Table 2 presents the basic
means for control. Appendix 1 shows the front panel of IFS7002.
Table 1
Conditions of the fire control panel
Indication
All conditions -
The fire control panel is power supplied
Indicator Power supply
continuous green light
Fire condition
Common indicator Fire condition
flashing red light

Table of Contents

Other manuals for UniPOS IFS7002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UniPOS IFS7002 and is the answer not in the manual?

UniPOS IFS7002 Specifications

General IconGeneral
BrandUniPOS
ModelIFS7002
CategoryControl Panel
LanguageEnglish

Related product manuals