14.9 Command: Until
Stopping a Direction Movement
You can add Direction Vector settings, for Tool Speed and Tool Acceleration, to define the
vector direction for linear motion, allowing for advanced uses as:
defining linear motion relative to multiple feature axes
computing the direction as a mathematical expression
The Direction Vectors defines a custom code expression that is resolved to a unit vector. For
example, for a vector of [2,1,0] the robot moves two units in the x direction for every unit in the
y direction, relative to the specified speed.
14.9 Command: Until
The program node Until defines a stop criterion for a motion. The robot moves along a path
and stops when contact is detected.