CLIMATE CONTROLLER C-46 - INSTALLATION AND OPERATION MANUAL
11
It is possible to select any of the available heating modes for the
heating function and any of the available cooling modes for the
cooling function. See sections above.
H/C switchover in slave mode
In this switchover mode, the Climate Controller C-46 switches
between heating and cooling mode controlled from an external
source.
There are two ways to set the Climate Controller C-46 in slave
mode:
• If the Bus slave function is selected from the H/C
switchover menu, the switchover function will be controlled
from a Controller C-56 Radio.
• If the General purpose input function is selected in either
the Bus master menu or the No bus menu, the switchover
function will be controlled from an external source. See
section 8.7.1
Bus master and No bus modes, page 30.
An external source can for example be a manual switch or a
heat pump.