3.3 Settings for Normal Operation
Switch settings for normal operation are as follows:
Main circuit breaker F1 ON
Window conditioner circuit breaker ON
Battery switch ON
Data message and interface configuration and the configuration of measuring
interval and transmission speed are standard factory settings. When required,
the settings can be changed by giving commands with the terminal.
During the factory alignment procedure, the optical adjustments are carefully
carried out to fulfill the requirements and specifications of the device. Optical
adjustments have been made at factory or depot, thus there is no need to
readjust in the field.
3.4 Factory settings of user programmable parameters
Table 3-1 next page shows the standard factory settings of user programmable
parameters. The prevailing parameter settings can be seen by the command
GET parameter_group
Parameter groups are displayed as bold text in table 3-1. As response to the
command a list of parameters with prevailing parameter values is shown.
The standard factory-set parameter values, which may be changed by the user,
are collected in the second column in table 3-1. The values displayed in the
first column are factory settings that the user cannot change. For changing a
value to the desired content and function, depending on the particular
installation, the corresponding command is
SET parameter_group parameter