4.1.2 FrontSide
LC‐Display(twolineswith16characterseach):
Data,serviceintervalsandmenuoptionsareshowninthetwolinesoftheilluminatedLCdisplay.
Thecurrentmenuoptionappearsintheupperline,whereasthelowerlinecontainsthecurrent
parameter
valuefordispensing,accordingtonumericaldatatobemodified.
Keypadwithtwelvesoftkeys:
Menuoptionstocontrolthesystemareselectedbymeansofthesekeys.
Detailsforchangingparametersetc.areexplainedinchapter4.2,page17.
Controllampforservicerequest:
Assoonasthislamp
lightsup,thevalvehastobereturnedtothemanufacturer(orlicensedsub‐
contractor)forregularperiodicmaintenance.
Controllampsforadjust:
Theadjustforthevalveisinternallymonitored;theresultisvisualizedbymeansofthesetwocontrol
lamps.
Green:ThevalueisOKandcanbe
confirmedby[enter].
Red:Thevalueistoohighandmustbeloweredaccordingtotheinstructionsofthismanual,seepage31.
Controllampforstatusofheating:
ThisredLEDindicatestheactivityoftheheating.ON,Heatingactivated,otherwiseOFF.