VTK‐VS‐BA‐004e‐B|UserManualMDS3200A | Communication Interfaces
39
7.1.2 RS‐232C Commands
Theavailablecommandsarelistedbelow.Theyareexplainedonthefollowingpages,to‐
getherwithshortexamples.
Eachsingleinstructioncanbetested,e.g.bymeansofthe“MDCCommunicator“software.
ThissoftwareiscontainedontheCDwhichisincludedinthedelivery.Informationabout
handlingandinstallation
ofthissoftwarepackagecanbefoundinchapter7.1.3(seepage
50).
RS‐232CCommands
ReactionTime
1. *ESR?
450ms
2. *IDN?
250ms
3. ADJUST:?
250ms
4. ADJUST:START
750ms
5. HEATER:1:OFF
250ms
6. HEATER:1:ON
250ms
7. KEY:ENTER?
250ms
8. KEY:ESCAPE?
250ms
9. LCD?
250ms
10. SYSTEM:KLOCK:OFF
250ms
11. SYSTEM:KLOCK:ON
250ms
12. TEMP:?
250ms
13. TEMP:<setpointin°C>
250ms
14. MAINT:STATUS
250ms
15. TRIGGER:SET:?
250ms
16. TRIGGER:ASET:?
250ms
17. TRIGGER:SET:<Rising>,<OpenTime>,<Falling>,<NeedleLift>,<NumberofPulses>,<Delay>
250ms
18. TRIGGER:SET:<Rising>,<OpenTime>,<Falling>,<NeedleLift>,<NumberofPulses>,<Delay>,1
1150ms
19. TRIGGER:ASET:<Rising>,<OpenTi me>,<Falling>,<NeedleLift>,<NumberofPulses>,<Delay>
250ms
20. TRIGGER:ASET:<Rising>,<OpenTi me>,<Falling>,<NeedleLift>,<NumberofPulses>,<Delay>,1
1150ms
21. VALVE:OPEN
250ms
22. VALVEAOPEN:
250ms
23. VALVE:OPEN:<Rising>,<OpenTime>,<Falling>,<NeedleLift>,<NumberofPulses>,<Delay>
250ms
24. VALVE:AOPEN:<Risin g>,<OpenTime>,<Falling>,<NeedleLift>,<NumberofPulses>,<Delay>
250ms
25. VALVE:UP
250ms
26. VALVE:DOWN
250ms
27. WRITE:LCD:<text>
250ms
28. SYSTEM:SHOW:CYCLES
250ms
29. SYSTEM:SHOW:VALVEID
250ms
30. SYSTEM:SHOW:CONTROLLERID
250ms
31. *OPC?
250ms
32. TAPPET:CLEAR
450ms
33. TAPPET:SET:?
450ms
34. NOZZLE:SET:?
450ms
35. NOZZLE:CLEAR
450ms
36. SYSTEM:SHOW:ACTORTEMP
250ms
37. HELP
250ms