4.3.3 Submenu“Heating“
Twodistinctoptions(MDH230teandMDH230tf)areavailabletoheatthenozzlesofthe
microdispenserMDS3200A.Thiswaythedynamicalviscosityofthefluidtobedispensedcanbe
controlled,forsomeliquidsdispensingwithoutheatingisevenimpossible.
Heatingmayalsoberequiredtoensureaconstant
processtemperature,orwhenthedispensing
hastotakeplaceaboveroomtemperature.
SelectionoftemperaturevaluesaswellasswitchingONandOFFoftheheatersiscarriedoutby
meansofthefunctionsillustratedbelow.
4.3.4 Submenu“Status“
Thefirstthreefunctions“Firmwareversion“,“ValveID“and“IDControlUnit“withtheparticular
serialnumbersrepresentimportantinformationwhenconsultingtheTechnicalSupport.
“Maint.Cycle”referstotheunitasawholeandcannotbemodifiedbytheuser.Forthenozzleand
thetappethowever,itis
possibletodetermineafixnumberofcyclesbeforereplacingtheconcern
ingitemsandtoresetthecountersafterexchange.“Error”showscorrespondingmessagesofthe
system.

