EasyManuals Logo

Viessmann Vitocell 360-M User Manual

Viessmann Vitocell 360-M
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
2.2 Specification
The collectors are available with 2 different absorber coatings. Type
SV1B/SH1B has a special absorber coating that allows these collec-
tors to be used in coastal regions.
Distance to the coast:
Up to 100 m:
Only use type SV1B/SH1B
100 to 1000 m:
Type SV1B/SH1B is recommended
Note
Viessmann accepts no liability if Vitosol 100-FM, type SV1F/SH1F is
used in these regions.
Specification
Type SV1F SH1F SV1B SH1B
Gross area
(required when applying for subsidies)
m
2
2.51 2.51 2.51 2.51
Absorber area
m
2
2.31 2.31 2.32 2.32
Aperture area
m
2
2.33 2.33 2.33 2.33
Spacing between collectors mm 21 21 21 21
Dimensions
Width mm 1056 2380 1056 2380
Height mm 2380 1056 2380 1056
Depth mm 73 73 72 72
Collector operating range output values
Optical efficiency
Absorber area
Gross area
% 81.3
74.9
81.4
74.9
Heat loss factor k
1
Absorber area
Gross area
W/(m
2
· K)
3.849
3.542
4.157
3.826
Heat loss factor k
2
Absorber area
Gross area
W/(m
2
· K
2
)
0.045
0.042
0.036
0.003
Theoretical output values across entire tempera-
ture range
Optical efficiency
Absorber area
Gross area
% 82.1
75.5
81.7
75.2
75.4
69.2
75.4
69.2
Heat loss factor k
1
Absorber area
Gross area
W/(m
2
· K)
4.854
4.468
4.640
4.270
4.15
3.81
4.15
3.81
Heat loss factor k
2
Absorber area
Gross area
W/(m
2
· K
2
)
0.023
0.021
0.026
0.024
0.0114
0.010
0.0114
0.010
Thermal capacity
kJ/(m
2
· K)
4.7 4.7 4.5 4.5
Weight kg 39 41 43.9 43.9
Liquid content
(heat transfer medium)
Litre 1.83 2.4 1.67 2.33
Permiss. operating pressure
With installation of an 8 bar safety valve (accessory)
bar/MPa
bar/MPa
6/0.6
8/0.8
6/0.6
8/0.8
6/0.6
8/0.8
6/0.6
8/0.8
Max. stagnation temperature °C 145 145 196 196
Steam-producing power
Favourable installation position
W/m
2
0
*1
0
*1
60 60
Unfavourable installation position
W/m
2
0
*1
0
*1
100 100
Connection Ø mm 22 22 22 22
Specification for determining the energy efficiency class (ErP label)
Type SV1F SH1F SV1B SH1B
Aperture area
m
2
2.33 2.33 2.33 2.33
The following values apply to the aperture area:
Collector efficiency η
col
, at a temperature differential
of 40 K
59 59 57.0 57.0
Optical efficiency in the collector % 81 81 75.4 75.4
Heat loss factor k
1
W/(m
2
· K)
4.81 4.6 4.14 4.14
Heat loss factor k
2
W/(m
2
· K
2
)
0.022 0.025 0.0114 0.0114
Incidence angle modifier IAM 0.89 0.89 0.89 0.89
*1
Provided manufacturer's specifications for the filling pressure of the solar thermal system are adhered to.
Vitosol 100-FM, type SV1F/SH1F and Vitosol 100-F, type SV1B/SH1B
(cont.)
VITOSOL
VIESMANN
11
5822 440 GB
2

Table of Contents

Other manuals for Viessmann Vitocell 360-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitocell 360-M and is the answer not in the manual?

Viessmann Vitocell 360-M Specifications

General IconGeneral
BrandViessmann
ModelVitocell 360-M
CategoryHeating System
LanguageEnglish

Related product manuals