7.2 Vitocell 100-B, type CVB/CVBB
For DHW heating in conjunction with boilers and solar collectors for
dual mode operation
Suitable for the following systems:
DHW temperature up to 95 °C
Heating water flow temperature up to 160 °C
Solar flow temperature up to 160 °C
Operating pressure on the heating water side up to 10 bar
(1.0 MPa)
Operating pressure on the solar side up to 10 bar (1.0 MPa)
Operating pressure on the DHW side up to 10 bar (1.0 MPa)
Specification
Type CVBB CVB CVB CVBB CVBB
Cylinder capacity l 300 400 500 750 950
Internal indirect coil Top Bot-
tom
Top Bot-
tom
Top Bot-
tom
Top Bot-
tom
Top Bot-
tom
DIN registration no. 9W242/11-13 MC/E Applied for
Continuous output
For DHW heating from 10 to 45 °C
and a heating water flow tempera-
ture of … at the heating water flow
rate stated below
90 °C
kW 31 53 42 63 47 70 76 114 90 122
l/h 761 1302 1032 1548 1154 1720 1866 2790 2221 2995
80 °C
kW 26 44 33 52 40 58 63 94 75 101
l/h 638 1081 811 1278 982 1425 1546 2311 1840 2482
70 °C
kW 20 33 25 39 30 45 49 73 58 78
l/h 491 811 614 958 737 1106 1200 1794 1428 1926
60 °C
kW 15 23 17 27 22 32 35 52 41 56
l/h 368 565 418 663 540 786 853 1275 1015 1369
50 °C
kW 11 18 10 13 16 24 26 39 31 42
l/h 270 442 246 319 393 589 639 955 760 1026
Continuous output
For DHW heating from 10 to 60 °C
and a heating water flow tempera-
ture of … at the heating water flow
rate stated below
90 °C
kW 23 45 36 56 36 53 59 79 67 85
l/h 395 774 619 963 619 911 1012 1359 1157 1465
80 °C
kW 20 34 27 42 30 44 49 66 56 71
l/h 344 584 464 722 516 756 840 1128 960 1216
70 °C
kW 15 23 18 29 22 33 37 49 42 53
l/h 258 395 310 499 378 567 630 846 720 912
Heating water flow rate for the stated con-
tinuous outputs
m
3
/h
3.0 3.0 3.0 3.0 3.0
Max. connectable heat pump output
At 55 °C heating water flow temperature
and 45 °C DHW temperature for the speci-
fied heating water flow rate (both internal
indirect coils connected in series)
kW 8 8 10
Standby heat loss to EN 12897:2006 Q
ST
at 45 K temperature differential
kWh/
24 h
1.65 1.80 1.95 2.28 2.48
Standby capacity V
aux
l 127 167 231 365 500
Solar capacity V
sol
l 173 233 269 385 450
Dimensions
Length (7)
Incl. thermal insulation a mm 667 859 859 1062 1062
Excl. thermal insulation mm 650 650 790 790
Total width
Incl. thermal insulation b mm 744 923 923 1110 1110
Excl. thermal insulation mm 881 881 1005 1005
Height
Incl. thermal insulation c mm 1734 1624 1948 1897 2197
Excl. thermal insulation mm 1518 1844 1797 2103
Height when tilted
Incl. thermal insulation mm 1825
Excl. thermal insulation mm 1550 1860 1980 2286
Weight incl. thermal insulation kg 166 167 205 320 390
Total weight in operation incl. immersion
heater
kg 468 569 707 1072 1342
Heating water capacity l 6 10 6.5 10.5 9 12.5 13.8 29.7 18.6 33.1
Heating surface
m
2
0.9 1.5 1.0 1.5 1.4 1.9 1.6 3.5 2.2 3.9
Connections
Upper indirect coil (male thread) R 1 1 1 1 1
Lower indirect coil (male thread) R 1 1 1
Cold water, DHW (male thread) R 1
DHW circulation (male thread) R 1 1 1
Immersion heater (female thread) Rp
Energy efficiency class B B B
DHW cylinders
(cont.)
VITOSOL
VIESMANN
45
5822 440 GB
7