Vitocell 340-M, type SVKC
TH
TH
k
l
i
h
g
f
e
d
m
HV1/EL
WW/Z
HV2/HR1
HR2
HR3
KW
E
HVs/HRs/ELs
ELH
n
ELH
o
b
a
HRs
HVs/ELs
TH
c
n
TR3
TR2
TR1
40°
E Drain outlet
EL Air vent valve
EL
s
Solar indirect coil, air vent valve
ELH Immersion heater (female connection Rp 1½)
HR Heating water return
HR
s
Heating water return, solar thermal system
HV Heating water flow
HV
s
Heating water flow, solar thermal system
KW Cold water
TH Retainer for thermometer sensor or additional sensor (clamp-
ing bracket)
TR Clamping system for fixing immersion temperature sensors to
the cylinder jacket. Retainers for 3 immersion temperature
sensors per clamping system.
WW DHW
Z DHW circulation (threaded DHW circulation fitting, accesso-
ries)
Dimensions
Cylinder capacity l 750 950
Length (7)
a mm 1064 1064
Width b mm 1119 1119
Height c mm 1900 2200
d mm 1787 2093
e mm 1558 1863
f mm 1038 1158
g mm 850 850
h mm 483 483
i mm 383 383
k mm 145 145
l mm 75 75
m mm 1009 1135
n mm 185 185
Length excl. thermal in-
sulation
o mm 790 790
DHW cylinders
(cont.)
66
VIESMANN
VITOSOL
7
5822 440 GB

Table of Contents

Other manuals for Viessmann Vitocell 360-M

Related product manuals