Disassembly/Assembly Mobile Generator
102 wc_tx000575gb.fm
9.13 Replacing the Emergency Stop Switch (older)
Turn off the generator before replacing the emergency stop switch.
Removal:
9.13.1 Slide the locking tab (a) to the unlock position and pull the switch off
the pushbutton.
9.13.2 Label and disconnect the wiring from the switch.
9.13.3 Remove the locking nut (b) and washer.
9.13.4 Remove the screws (c) that secure the pushbutton and remove the
pushbutton.
Installation:
9.13.5 Slide the pushbutton portion through the door.
Note: Position the pushbutton with “TOP” marking facing up.
Secure the pushbutton with screws (c).
9.13.6 Attach washer and locking nut (b).
9.13.7 Reconnect the wiring.
9.13.8 Attach the switch to the pushbutton and slide the locking tab (a) to the
locked position.