Disassembly/Assembly Mobile Generator
104 wc_tx000575gb.fm
9.14 Replacing the Emergency Stop Switch (newer)
See Graphic: wc_gr003677
Turn off the generator and disconnect the battery before replacing the
emergency stop switch.
Removal:
9.14.1 Slide the locking tab (a) to the unlock position and pull the contact
block (b) off the pushbutton (c) portion of the switch.
9.14.2 Label and disconnect the wiring from the contact block.
9.14.3 Remove the locking nut (d) and washer (e), and remove the
pushbutton portion of the switch.
Installation:
9.14.4 Slide the rubber washer (f) onto the pushbutton portion of the switch,
then insert the pushbutton through the door.
9.14.5 Align the washer so that the tab (g) is 180° from the notch (h) in the
door. Slide the washer onto the pushbutton so that the tab of the
washer fits in the groove (i) of the pushbutton. Secure the pushbutton
with the locking nut (d).
9.14.6 Reconnect the wiring to the contact block.
9.14.7 Attach the contact block to the pushbutton and slide the locking tab (a)
to the locked position.

Table of Contents

Other manuals for Wacker Neuson G 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson G 85 and is the answer not in the manual?

Wacker Neuson G 85 Specifications

General IconGeneral
BrandWacker Neuson
ModelG 85
CategoryPortable Generator
LanguageEnglish

Related product manuals