75
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2329371
Fault number Fault Cause Remedy
E15-E17 High-voltage
generator error
Hardware defect If problem persists, contact
Wagner Service Team
Switch o unit and after
10seconds, switch on again
E18 Result of corona
measurement is
implausible
Hardware defect If problem persists, contact
Wagner Service Team
E20 Password error The password for enabling
the device is not set or has
been lost
Inform Wagner service
center
E21-E25 Exception error Hardware defect has
occurred
If problem persists, contact
Wagner Service Team
E31 Gun switch
monitoring in
automatic mode
The gun switch line has
been interrupted
Check gun cable
Gun unplugged during
operation
Check gun
E41 No ow of atomizing
air
No air is owing out of the
control unit
Causes:
Check:
Hose kinked / blocked The hose laying
Gun blocked The air supply to the
control unit
Input pressure > 6 bar
Compressed air switched
o
Open compressed air
E42 No ow of dosing air No air is owing out of the
control unit
Causes:
Check:
Hose kinked / blocked The hose laying
The air supply to the
control unit
Input pressure > 6 bar
Injector is not connected Connect injector
Compressed air switched
o
Open compressed air