76
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2329371
Fault number Fault Cause Remedy
E43 No ow of feed air No air is owing out of the
control unit
Causes:
Gun unplugged during
operation
Check:
Hose kinked / blocked The hose laying
The air supply to the
control unit
Input pressure > 6 bar
Injector is not connected Connect injector
Compressed air switched
o
Open compressed air
E51-E53 Exception error
Hardware defect has
occurred
If problem persists, contact
Wagner Service Team
E54 Hardware error
Hardware defect has
occurred
Detach hose on rear of
valve and in standby
mode, check the valve for
seal integrity (air supply
must be connected)
Atomizing air duct valve
leaking
E55 Hardware error
Hardware defect has
occurred
Detach hose on rear of
valve and in standby
mode, check the valve for
seal integrity (air supply
must be connected)
Dosing air duct valve
leaking
E56 Hardware error
Hardware defect has
occurred
Detach hose on rear of
valve and in standby
mode, check the valve for
seal integrity (air supply
must be connected)
Feed air duct valve leaking
E60 Operation without
external release (only
for manual gun with
external control)
No release from Check external control
Missing or defective
wiring