66
wallaceperimetersecurity.comPhone: 866.300.1110
PRIMARY & SECONDARY OPERATOR FOR A STANDARD POST DRIVE GATE SPEEDGATE
Single or dual motor applicaons may be installed, depending upon gate conguraon.
• If a single folding gate is required, up to 11.5 feet (3.5m)- PDXT Series [or 12 feet (3.66m)- PDTT Series]
wide, only two folding gate panels hinged together, one (primary) operator and one column housing
one gate motor are required. The remaining column is ulized to mount exterior photo eyes, as is the
rst.
• If a dual folding gate is required, up to 23 feet (7.01m)- PDXT Series [or 24 feet (7.31m)- PDTT Series]
wide, four folding gate panels (two panels to fold one way; two panels to fold the other way), both
operators (primary and secondary) and two columns housing one gate motor each are required. Photo
eyes are mounted on each column exterior.
It is important to consider not only
user vehicle trac size and type when
ascertaining whether to employ a
single or a dual conguraon, but also
how vehicles will be entering the gate.
For example, straight-in or requiring
hard 90-degree turns in a limited
zone of space, in which case a dual
conguraon should be employed,
even if user vehicles are deemed
smaller-sized.