113
Programme unit
1 2 3
4 5 6
7 8 9
0
Water level for quick cool-down
Here you determine the level to which the machine
llswithcoldwaterforquickcool-down.
When you are creating a wash program, in the mo-
dule”COOL-DOWN”thereisanoptionforprogram-
ming”QUICKCOOL-DOWN”.
Quickcool-downmeansthatthemachinewillll
with cold water to a higher level.
This function is used mainly for reducing the tempe-
rature of the water before it is discharged.
For information on the levels used for the various
machines, see the manual ”Programming, PCS
Program Control Unit”.
Water level
Level,quickcool-down
The machine fills
with cold water
Time
Water level during wash
DISPLAY ACTUAL SPEED Y
MACHINE NOT HEATED N
TEMPERATURE CONTROL OF WATER Y
TEMPERATURE IN °C Y
REPEAT PROGR. MODE QUESTION N
LOCKED STANDARD WASH PROGRAMS N
LEVEL QUICK COOL- DOWN 175
LEVEL UNBALANCE 0
LEVEL LOW 135
LEVEL MEDIUM 150
LEVEL HIGH 175
MIDDLETEMPERATURECOOL-DOWN70°C
DEFAULT MOTOR ON TIME 0:12
DEFAULT MOTOR OFF TIME 0:03
FLUSH DELAY TIME 0:06
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
No access to standard programs
Here you determine whether the user will have ac-
cess to the machine’s standard programs (numbe-
red991-999)ornot.
If you answer Yes (Y):
The user will not have access to the standard
programs.
If you answer No (N):
The user will have access to the standard
programs.
DISPLAY ACTUAL TEMPERATURE Y
DISPLAY ACTUAL SPEED Y
MACHINE NOT HEATED N
TEMPERATURE CONTROL OF WATER Y
TEMPERATURE IN °C Y
REPEAT PROGR. MODE QUESTION N
LOCKED STANDARD WASH PROGRAMS N
LEVELQUICKCOOL-DOWN 175
LEVEL UNBALANCE 0
LEVEL LOW 135
LEVEL MEDIUM 150
LEVEL HIGH 175
MIDDLETEMPERATURECOOL-DOWN70°C
DEFAULT MOTOR ON TIME 0:12
DEFAULT MOTOR OFF TIME 0:03
Y/N
Answer Yes (Y) or No (N).
Press .