118
Programme unit
1 2 3
4 5 6
7 8 9
0
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y
BUZZER TIMEOUT AT END Y
BUZZER TIMEOUT AT PAUS Y
ERROR, OVERFILLED Y
PASSWORD ACTIVE Y
CMIS ADDRESS 0
LEVEL IN MM ACTIVE Y
START SLOW FILLING, HG 10
OFFSET LEVEL, HG 2
READY
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y
BUZZER TIMEOUT AT END Y
BUZZER TIMEOUT AT PAUS Y
ERROR, OVERFILLED Y
PASSWORD ACTIVE Y
CMIS ADDRESS 0
LEVEL IN MM ACTIVE Y
START SLOW FILLING, HG 10
OFFSET LEVEL, HG 2
READY
Y/N
PC5, Power Control
Here you determine whether input X15 on I/O
PCB 1 (external pause signal) will have the ”ex-
ternal pause signal” function (for this, the letter
”N” (No) should be inserted on both option lines),
or the Power Control (PC5) function. For detailed
instructions on PC5 connection and settings, see
relevant manual section.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Answer Yes (Y) or No (N).
Press .
Show weight timeout
Here you determine the length of time the weight
will be displayed, before the normal display is
restored.
Weight dis-
play mode
CLARUS CONTROL
WEIGHT, KG:
007,0

Table of Contents