144
Programme unit
ERROR, EWD INTERLOCK Y
ERROR, I/O COMMUNICATION Y
ERROR, LOW OIL LEVEL Y
ERROR, LOW OR HIGH VOLTAGE Y
ERROR, ERROR CODES FROM MOTOR Y
ERROR, PRESS SENSOR TILT Y
ERROR, PRESSURE SENSOR TIMEOUT Y
ERROR, DOOR SWITCH TILT Y
ERROR, LEVEL OFFSET Y
ERROR, LEVEL SYSTEM NOT CALIB. Y
TIME DELAY BEFORE DOOR OPENING 0:30
UPPER TEMPERATURE FOR ERROR 98°C
LOWERTEMPERATUREFORERROR -9°C
MAX ADJUST TEMPERATURE 97°C
MAXIMUM EXTRACT SPEED 825
DEFAULT WASH SPEED 37
1 2 3
4 5 6
7 8 9
0
ERROR, I/O COMMUNICATION Y
ERROR, LOW OIL LEVEL Y
ERROR, LOW OR HIGH VOLTAGE Y
ERROR, ERROR CODES FROM MOTOR Y
ERROR, PRESS SENSOR TILT Y
ERROR, PRESSURE SENSOR TIMEOUT Y
ERROR, DOOR SWITCH TILT Y
ERROR, LEVEL OFFSET Y
ERROR, LEVEL SYSTEM NOT CALIB. Y
TIME DELAY BEFORE DOOR OPENING 0:30
UPPER TEMPERATURE FOR ERROR 98°C
LOWER TEMPERATURE FOR ERROR -9°C
MAX ADJUST TEMPERATURE 97°C
MAXIMUM EXTRACT SPEED 825
DEFAULT WASH SPEED 37
DISTRIBUTION SPEED 63
1 2 3
4 5 6
7 8 9
0
Time delay before door opening
Here you determine the length of time during which
the door will be prevented from opening if the
machinehasdetectedafault-errorandisdis-
playing an error message. This must give enough
time for the water to empty and drum speed to be
reduced.
Please note that the water will not be emptied
as a result of all types of error. In the case of the
HIGH TEMPERATURE error, for example, the door
will remain locked even though the time you have
programmed has elapsed. One reason for this is
to prevent the risk of a fire if the electrical heating
equipment is still switched on and heating.
Upper and lower temperature limits for
errors
Here you determine the temperature limits for the
errors HIGH TEMPERATURE and LOW TEMPERA-
TURE respectively.
IftheHIGHTEMPERATUREerrorisagged,this
usually indicates an short circuit in the sensor or
wiring. LOW TEMPERATURE usually indicates a
open circuit in sensor or wiring. That is why the
defaultvalueforthelowtemperaturelimitis-9C.If
the sensor cools to this temperature, the resistance
from the sensor will be 0 ohms, which corresponds
toashort-circuit.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .